Loading...
 
 Warning
  • User not in any of the required groups for GroupSelector field

100

Selected Document Category:Published Document
Source:Nanotechnology Characterization Laboratory
Anticipated Publication Year:
Publication Year:2011
Acronym:NCL
Identifier:STE-1.1
Document Title:Detection and Quantification of Gr am Negative Bacterial Endotoxin Contamination in Nanopart icle Formulations by End Point Chromogenic LAL Assay
url:http://ncl.cancer.gov/NCL_Method_STE-1.1.pdf
Scope:

This document describes a protocol for a quantitative detection of Gram negative bacterial
endotoxin in nanoparticle preparations using an end-point Limulus Amebocyte Lysate (LAL)
assay. The protocol is based on the QCL-1000 kit manufactured by BioWhittaker/Cambrex
Corporation(1)and the USP standard 85 “Bacterial endotoxin test”(2).

Keywords:endotoxin,LAL, QCL-1000
Type of Document:e. Specification
Issues Areas:Measurement and Characterizations
Health, Safety, and Environment
Primary Category:Chemicals e.g. pesticides, pharmaceuticals, paints, basic chemicals
Additional Categories
Goal or Need:
Intended Stakeholders:
Is it Being Implemented:
Submitter's Name:Admin
Submitter's e-mail:[email protected]
Submitter's Company:ANSI
Additional Comments:
Contact for Additional Info:http://ncl.cancer.gov/working_assay-cascade_download.asp



::::